Medical image – based computational model of pulsatile flow in saccular aneurisms

Stéphanie Salmon; Marc Thiriet; Jean-Frédéric Gerbeau

ESAIM: Mathematical Modelling and Numerical Analysis - Modélisation Mathématique et Analyse Numérique (2003)

  • Volume: 37, Issue: 4, page 663-679
  • ISSN: 0764-583X

Abstract

top
Saccular aneurisms, swelling of a blood vessel, are investigated in order (i) to estimate the development risk of the wall lesion, before and after intravascular treatment, assuming that the pressure is the major factor, and (ii) to better plan medical interventions. Numerical simulations, using the finite element method, are performed in three-dimensional aneurisms. Computational meshes are derived from medical imaging data to take into account both between-subject and within-subject anatomical variability of the diseased vessel segment. The 3D reconstruction is associated with a faceted surface. A geometrical model is then obtained to be finally meshed for a finite element use. The pulsatile flow of incompressible newtonian blood is illustrated by numerical simulations carried out in two saccular aneurism types, a side- and a terminal-aneurism. High pressure zones are observed in the aneurism cavity, especially in the terminal one.

How to cite

top

Salmon, Stéphanie, Thiriet, Marc, and Gerbeau, Jean-Frédéric. "Medical image – based computational model of pulsatile flow in saccular aneurisms." ESAIM: Mathematical Modelling and Numerical Analysis - Modélisation Mathématique et Analyse Numérique 37.4 (2003): 663-679. <http://eudml.org/doc/244948>.

@article{Salmon2003,
abstract = {Saccular aneurisms, swelling of a blood vessel, are investigated in order (i) to estimate the development risk of the wall lesion, before and after intravascular treatment, assuming that the pressure is the major factor, and (ii) to better plan medical interventions. Numerical simulations, using the finite element method, are performed in three-dimensional aneurisms. Computational meshes are derived from medical imaging data to take into account both between-subject and within-subject anatomical variability of the diseased vessel segment. The 3D reconstruction is associated with a faceted surface. A geometrical model is then obtained to be finally meshed for a finite element use. The pulsatile flow of incompressible newtonian blood is illustrated by numerical simulations carried out in two saccular aneurism types, a side- and a terminal-aneurism. High pressure zones are observed in the aneurism cavity, especially in the terminal one.},
author = {Salmon, Stéphanie, Thiriet, Marc, Gerbeau, Jean-Frédéric},
journal = {ESAIM: Mathematical Modelling and Numerical Analysis - Modélisation Mathématique et Analyse Numérique},
keywords = {3D surface reconstruction; finite element method; medical images; mesh generation; Navier–Stokes equations; Navier-Stokes equations},
language = {eng},
number = {4},
pages = {663-679},
publisher = {EDP-Sciences},
title = {Medical image – based computational model of pulsatile flow in saccular aneurisms},
url = {http://eudml.org/doc/244948},
volume = {37},
year = {2003},
}

TY - JOUR
AU - Salmon, Stéphanie
AU - Thiriet, Marc
AU - Gerbeau, Jean-Frédéric
TI - Medical image – based computational model of pulsatile flow in saccular aneurisms
JO - ESAIM: Mathematical Modelling and Numerical Analysis - Modélisation Mathématique et Analyse Numérique
PY - 2003
PB - EDP-Sciences
VL - 37
IS - 4
SP - 663
EP - 679
AB - Saccular aneurisms, swelling of a blood vessel, are investigated in order (i) to estimate the development risk of the wall lesion, before and after intravascular treatment, assuming that the pressure is the major factor, and (ii) to better plan medical interventions. Numerical simulations, using the finite element method, are performed in three-dimensional aneurisms. Computational meshes are derived from medical imaging data to take into account both between-subject and within-subject anatomical variability of the diseased vessel segment. The 3D reconstruction is associated with a faceted surface. A geometrical model is then obtained to be finally meshed for a finite element use. The pulsatile flow of incompressible newtonian blood is illustrated by numerical simulations carried out in two saccular aneurism types, a side- and a terminal-aneurism. High pressure zones are observed in the aneurism cavity, especially in the terminal one.
LA - eng
KW - 3D surface reconstruction; finite element method; medical images; mesh generation; Navier–Stokes equations; Navier-Stokes equations
UR - http://eudml.org/doc/244948
ER -

References

top
  1. [1] D.N. Arnold, F. Brezzi and M. Fortin, A stable finite element for the Stokes equations. Calcolo 21 (1984) 337–344. Zbl0593.76039
  2. [2] J.-D. Boissonnat and M. Yvinec, Algorithmic Geometry. Cambridge University Press, UK (1998). Zbl0917.68212MR1631175
  3. [3] J.-D. Boissonat, R. Chaine, P. Frey, J.F. Gerbeau, G. Malandain, F. Nicoud, S. Salmon, E. Saltel and M. Thiriet, From medical images to computational blood flow models. INRIA Research Report (2003). 
  4. [4] V.D. Butty, K. Gudjonsson, P. Buchel, V.B. Makhijani, Y. Ventikos and D. Polikakos, Residence time and basins of attraction for a realistic right internal carotid artery with two aneurysms. Biorheology 39 (2002) 387–393. 
  5. [5] S. Chien, Shear dependence of effective cell volume as a determinant of blood viscosity. Science 168 (1970) 977–978. 
  6. [6] S. Chien, Biophysical behavior in suspensions, in The Red Blod Cell, D. Surgenor Ed., Academic Press, New York (1975). 
  7. [7] P.G. Ciarlet, The finite element method for elliptic problems. Stud. Math. Appl. 4 (1978). Zbl0383.65058MR520174
  8. [8] G.G. Ferguson, Physical factors in the initiation, growth and rupture of human intracranial saccular aneurysms. J. Neurosurg. 37 (1972) 666–677. 
  9. [9] P. Frey, A fully automatic adaptive isotropic surface remeshing procedure. INRIA Research Report 0252 (2001). 
  10. [10] J.-F. Gerbeau and M. Vidrascu, A Quasi-Newton Algorithm Based on a Reduced Model for Fluid-Structure Interaction Problems in Blood Flows. INRIA Research Report 4691 (2001). Zbl1070.74047
  11. [11] P.L. George, F. Hecht and E. Saltel, TetMesh (distributed by SIMULOG). 
  12. [12] R. Glowinski, Numerical methods for nonlinear variational problems. Springer Ser. Comput. Phys. (1984). Zbl0536.65054MR737005
  13. [13] F. Hecht and C. Parès, NSP1B3 : un logiciel pour résoudre les équations de Navier Stokes incompressible 3D. INRIA Research Report 1449 (1991). 
  14. [14] T.M. Liou and S.N. Liou, A review on in vitro studies of hemodynamic characteristics in terminal and lateral aneurysm models. Proc. Natl. Sci. Counc. ROC(B) 4 (1999) 133–148. 
  15. [15] W.E. Lorensen and H.E. Cline, Marching cubes: A high resolution 3D surface construction algorithm. Comput. Graphics 21 (1987) 163–169. 
  16. [16] J.-B. Mossa, Simulation d’une bifurcation artérielle. CERFACS Report (2001). 
  17. [17] K. Perktold, R. Peter and M. Resch, Pulsatile non-newtonian blood flow simulation through a bifurcation with an aneurysm. Biorheology 26 (1989) 1011–1030. 
  18. [18] O. Pironneau, On the transport-diffusion algorithm and its application to the Navier-Stokes equations. Numerische Mathematik 38 (1982) 309–332. Zbl0505.76100
  19. [19] H.J. Steiger, D.W. Liepsch, A. Poll and H.J. Reulen, Hemodynamic stress in terminal saccular aneurysms: a laser-Doppler study. Heart Vessels 4 (1988) 162–169. 
  20. [20] D.A. Steinman, J.S. Milner, C.J. Norley, S.P. Lownie and D.W. Holdsworth, Image-based computational simulation of flow dynamics in a giant intracranial aneurysm. AJNR Am. J. Neuroradiol. 24 (2003) 559–566 
  21. [21] G. Taubin, Curve and surface smoothing without shrinkage, in 5th Int. Conf. on Computer Vision Proc. (1995) 852–857. 
  22. [22] M. Thiriet, G. Martin-Borret and F. Hecht, Ecoulement rhéofluidifiant dans un coude et une bifurcation plane symétrique. Application à l’écoulement sanguin dans la grande circulation. J. Phys. III France 6 (1996) 529–542. 
  23. [23] M. Thiriet et al., Apports et limitations de la vélocimétrie par résonance magnétique nucléaire en biomécanique. Mesures dans un embranchement plan symétrique. J. Phys. III France 7 (1997) 771–787. 
  24. [24] M. Thiriet, P. Brugières, J. Bittoun and A. Gaston, Computational flow models in cerebral congenital aneurisms: I. Steady flow. Méca. Ind. 2 (2001) 107–118. 
  25. [25] M. Thiriet, S. Naili and C. Ribreau, Entry length and wall shear stress in uniformly collapsed-pipe flow. Comput. Model. Engrg. Sci. 4 (2003) No. 3 and 4. Zbl1048.76533

NotesEmbed ?

top

You must be logged in to post comments.

To embed these notes on your page include the following JavaScript code on your page where you want the notes to appear.

Only the controls for the widget will be shown in your chosen language. Notes will be shown in their authored language.

Tells the widget how many notes to show per page. You can cycle through additional notes using the next and previous controls.

    
                

Note: Best practice suggests putting the JavaScript code just before the closing </body> tag.